SVE-DS2200
.
.
CCD can automatic positioning dispensing spot
CCD measures and calibrates syringe tip position
Programmable motion of the dispensing head position
10 sets of high-precision linear motors to target syringe tip location
Achieving high productivity by implementing of multi-point and multi-syringe dispensing
10 sets of independent programmable pneumatic controllers to precisely control adhesive
Backlight module w/o equidistant can also perform accurate dispensing
SVE-DS2200 Backlight Module Automatic Positioning Dispensing Equipment | ||||
Category | Item | SPEC | ||
X, Y axis carrying module | AC servo motor | Min. accuracy | 1μm/pulse | |
Repeatability | ±0.02mm | |||
Displacement accuracy | 0.02mm | |||
Accelerating and decelerating mode | T type accelerating/decelerating control | |||
Dispensing speed | 500mm/s (adjustable) | |||
Z axis driver | AC servo motor | Max. speed | 150mm/s (adjustable) | |
Min. accuracy | 1μm/pulse | |||
Repeatability | ±0.01mm | |||
Displacement accuracy | 0.01mm | |||
Dispensing module | X direction auto-adjustment pitch | Program setting | ||
Dispensing head | 10 sets | |||
X-axis length | 900mm | |||
Min. distance between dispensing heads | 60mm | |||
Syringe tip, multi-points dispensing | Based on customer design | |||
Syringe compatibility | 30 cc | |||
Syringe tips protection & fixture | Fix needle seat,, Pin press down | |||
Dispensing method | Air pressure control | |||
Magnetic scale monitor/control | ± 15μm/m | |||
Manual fine-tune stroke | Y,Z axis manual fine-tuning: Y ± 3mm. Z ± 3mm (micrometer caliper) | |||
Track | Leadframe dimension | 1000mm(L)*450mm(W) | ||
Leadframe transferring method | Belt conveyor mode | Motor-driven belt conveyor | ||
Dispensing working zone | Cylinder positioning, CCD detecting | |||
Loader | Air compressor w/ sensor protection | |||
Track width adjustment mode | Manual adjustment | Track width adjustment range | ||
Max:450 mm | ||||
Min :200 mm | ||||
Leadframe positioning mode | X-direction positioning | Reflective optical sensor to detect position | ||
Lateral positioning | Lateral module | |||
Image processing to identify and rectify leadframe position | ||||
Leadframe mask press-down mode | Air-driven press module | |||
Protection | Sensor detection mechanism | |||
Dispensing Controller | Pneumatic 10-syringe capacity dispensing controllers | Dispensing accuracy within ± 1ms | ||
Buffer tank | 5L Buffer tank x 2 (Plug-in add-on) | |||
Visual Module | Alignment CCD | 1/2in CCD | Calibrating the position of syringe | |
Z axis CCD | 1/2in CCD | Examining if leadframe carries any void. If so, dispenser will skip the void and move to next LED unit | ||
Compressed air | Output pressure | Standard 6.0 kgf / c㎡ --300 litter/min | ||
Exterior | External dimension | 1700(W) × 2000(L) × 1800(H)mm | ||
Weight | Approximately 2000 kg | |||
Power source | Input Power | Voltage | one-phase,AC 200~240V ± 10% 2000W | |
Wave frequency | 50/60Hz | |||
User Interface | Windows XP |